imx OMEGA
Automation and closed-loop control of test systems
The modern testing software
DUT management
Parameterization of tests
Limit monitoring
Visualization of measurement data
automated evaluation
Language German / English
With one click from starting a test
to the PDF report
Control
The test specimen information must first be selected in the control unit. After selecting the desired test type and the associated test parameters, the test can be started.
Information
During the test, the status will be displayed. If an error occurs, it is displayed with an error number and description.
Curve window
Display of curves or individual values during the current measurement. In addition, thermometers or other widgets can be used to display the measured values.
Configurator
Test parameters, the test specimen, etc. can be adjusted in the Configurator.
Panel
The test stand is operated and the measurement data is visualized in the panel (current display).
User management
The software has three user levels that can be assigned different rights. Each user of the software is assigned a corresponding level.
Evaluation
The results of the evaluation are stored as a PDF report and in the raw data folder. The evaluation is carried out automatically or manually in separate software.
Navigation
The buttons can be used to quickly switch to the different panel views.
Parameterization of DUT information and test sequences
In the Configurator view, the DUT-specific information and limit values that are monitored during the test can be customized. The parameters of the test types are divided into those that control the test sequence and those that are used in the evaluation. These can be created and configured independently.
The test plans, which are optionally available as an add-on, enable the cyclic repetition and sequencing of predefined tests. This allows the DUT to be assigned a sequence of tests that the user does not have to start manually, so that the tests can run overnight, over the weekend, or over a longer period of time (endurance tests).
Measurement information
Metadata such as test item serial number, note on test
DUT configuration
Definition of DUT limits and properties
Test configuration
Defining parameters for the test sequence and evaluation
Testplan
Combining individual test types into an automated test plan
End-Of-Line
Assignment of test specimen properties and test plan or individual test to an EOL key. This key can be assigned to a barcode, for example.
Test parameter sets
Selection of different parameter sets for the test sequence
test parameter set
Create, change and save parameters for the selected parameter set
Evaluation parameter sets
Selection of different parameter sets for the evaluation
Evaluation parameter set
Create, change and save parameters for the selected parameter set
Add-ons for imx OMEGA
Testplans
Combine single tests into an automated test plan. Within a test plan, repetitions and timeouts can be included so that the test stand can be operated without operator supervision.
End-of-Line
Operating the test bench without mouse and keyboard. Loading predefined parameter sets and starting test plans or singele tests can be linked to various events, such as scanning a barcode.
imx GraphiPEd
Edit individual curve shapes comfortably in the graphical editor. This provides a live preview of the sequence in the correct time frame and allows convenient inserting and editing of jumps, ramps etc.